ojs2 has produced an error Message: USER NOTICE: Deprecated function. In file: /var/www/widyariset/classes/article/Article.inc.php At line: 76 Stacktrace: Server info: OS: Linux PHP Version: 5.6.33-1+ubuntu16.04.1+deb.sury.org+1 Apache Version: Apache/2.4.18 (Ubuntu) DB Driver: mysql DB server version: 5.7.22-0ubuntu0.16.04.1
THE EFFECT OF CHARGING CONDITION FOR CONDUCTED EMISSION VALUE OF INFORMATION TECHNOLOGY EQUIPMENT | Wirapraja | Widyariset

THE EFFECT OF CHARGING CONDITION FOR CONDUCTED EMISSION VALUE OF INFORMATION TECHNOLOGY EQUIPMENT

Agung Yanuar Wirapraja, Ika Prawesty Wulandari

Abstract


Currently, IT devices, especially mobile phone and notebook, have become a staple for humans. These devices can’t be separated from human activities. Mobile phone or notebook using those are too often can lead people to conduct any charging process when that device is being used. In general, there are three conditions for any devices when the charging process is being performed, such as: off, standby, and normal use (music on). This research objective is to compare the result on conducted emis- sion testing when mobile phone and notebook at the plugging charge for the conditions: off, stand by, and normal use (music on). Testing method refers to CISPR 22 Standards at Clause Mains Terminal Disturbance Voltage. Testing result for mobile phone and notebook show that all of testing sample perform conducted emission value with quasi peak value meet the requirement of CISPR 22. The amount of 80% testing sample, perform the highest quasipeak margin value when the off condition of devices.


Keywords


Mobile phone; Notebook; Standby; Conducted emissioni; Quasipeak

Full Text:

References


Armstrong, Keith. 2011.“Guide to Testing Conducted Emissions (Based on the Methods in EN 55022 and EN55011).”In Compliance. http://110www.incompliancemag.com/DigEd/inc1107/offline/download.pdf.

Balmori, Alfonso. 2009. “Electromagnetic Pollution from Phone Masts. Effects on Wildlife.” Pathophysiology 16 (2–3):191–99.doi:10.1016/j.pathophys.2009.01.007.

Battung, Rut O., Jimmy F. Rumampuk, and Wenny Supit. 2013. “Hubungan Radiasi Gelombang Elektromagnetik Telepon Seluler terhadap Fungsi Pendengaran Mahasiswa Angkatan 2009 Fakultas Kedokteran Universitas Sam Ratulangi Manado.” Jurnal E-Biomedik (eBM)1 (2): 1047–52.

Bellinger, David B., Bradley M. Budde, Moe Machida, Gary B. Richardson, and William P. Berg. 2009. “The Effect of Cellular Telephone Conversation and Music Listening on Response Time in Braking.”Transportation Research Part F:Traffic Psychology and Behaviour 12 (6): 441–51. doi:10.1016/j.trf.2009.08.007.

Braun, Stephan. 2011. “A Novel Time Domain EMI Measurement System for Measurement and Evaluation of Discontinuous Disturbance according to CISPR 14 and CISPR 16.”IEEE International Symposium on Electromagnetic Compatibility, 480–83.doi:10.1109/ISEMC.2011.6038359.

Galeev, A. 2000. “The Effects of Microwave Radiation from Mobile Telephones on Humans and Animals.”Neuroscience and Behavioral Physiology 30 (2): 187–94. doi:10.1007/BF02463157.

Harlacher, B.L., and R.W. Stewart. 2001.“Common Mode Voltage Measurements Comparison for CISPR 22 Conducted Emissions Measurements.”In 2001 IEEE EMC International Symposium.Symposium Record.International Symposium on Electromagnetic Compatibility (Cat.No.01CH37161),1:26–30.doi:10.1109/ISEMC.2001.950516.

Kaur, Mandeep, Shikha Kakar, and Danvir Mandal. 2011. “Electromagnetic

Interference.” 2011 3rd International Conference on Electronics Computer Technology 4: 1–5. doi:10.1109/ICECTECH.2011.5941844.

Lapinsky, S E, and A C Easty. 2006.“Electromagnetic Interference in Critical Care.” J.Crit Care 21 (3):267–70. papers3://publication/uuid/FC51C31C-C742-4EC9-B5C7503A6C2A0F2F.

Swamardika, I.B. Alit. 2009. “Pengaruh Radiasi Gelombang Elektromagnetik terhadap Kesehatan Manusia.”Teknologi Elektro 8 (1):106–9.

Tri, Jeffrey L, Rodney P Severson, Allen R Firl, David L Hayes, and John P Abenstein. 2005. “Cellular Telephone Interference with Medical Equipment.”Mayo Clinic Proceedings.Mayo Clinic 80 (10): 1286–90.doi:10.4065/80.10.1286.

Wallin, Mats K E B, Therese Marve, and Peter K Hakansson. 2005.“Modern Wireless Telecommunication Technologies and Their Electromagnetic Compatibility with Life-Supporting Equipment.”Anesthesia and Analgesia 101 (5):1393–1400.doi:10.1213/01.ANE.0000180216.83554.00.




DOI: http://dx.doi.org/10.14203/widyariset.4.1.2018.103-112

Refbacks

  • There are currently no refbacks.




Copyright (c) 2018 Widyariset

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.

Indexed by :