THERMAL PERFORMANCE OF TRADITIONAL HOUSE UMA KBUBU

Rini Nugrahaeni, I Ketut Suwantara

Abstract


This study identified thermal performances of Uma Kbubu in Maslete village, which include the character
of thermal building and thermal comfort of occupants. Thermal values was measured by Hioki data Logger, Thermocouple
type T, Questemp 34, Anometer Kanomax, and closed questioner to get thermal responsed of occupants.
Data was analysed by linear regression and comparation of building’s thermal characteristic between rainy and
dry season. Study shows that Uma Kbubu has good thermal performance in rainy and dry season, and capable
of creating thermal comfort for its occupants. Roof as building envelope has significant influence to thermal
performance of Uma Kbubu, while the wall had no significant effect. Neutral temperature was 24,6oC on rainy
season and 27,6 oC on dry season.

Keywords


Thermal performance, Character thermal, Thermal comfort, Uma Kbubu traditional house